t times are comparable only under like conditions as to temperature. Data to be used for this purpose are given in the Appendix. Neglect of this correction is frequently an avoidable source of error and annoyance in otherwise excellent work. The temperature of all solutions at the time of standardization should be recorded to facilitate the application of temperature corrections, if such are necessary at any later time. CALIBRATION OF THE BURETTES Two burettes, one at least of which should have a glass stopper, are required throughout the volumetric work. Both burettes should be calibrated by the student to whom they are assigned. PROCEDURE.--Weigh a 50 cc., flat-bottomed flask (preferably a light-weight flask), which must be dry on the outside, to the nearest centigram. Record the weight in the notebook. (See Appendix for suggestions as to records.) Place the flask under the burette and draw out into it about 10 cc. of water, removing any drop on the tip by touching it against the inside of the neck of the flask. Do not attempt to stop exactly at the 10 cc. mark, but do not vary more than 0.1 cc. from it. Note the time, and at the expiration of three minutes (or longer) read the burette accurately, and record the reading in the notebook (Note 1). Meanwhile weigh the flask and water to centigrams and record its weight (Note 2). Draw off the liquid from 10 cc. to about 20 cc. into the same flask without emptying it; weigh, and at the expiration of three minutes take the reading, and so on throughout the length of the burette. When it is completed, refill the burette and check the first calibration. The differences in readings represent the apparent volumes, the differences in weights the true volumes. For example, if an apparent volume of 10.05 cc. is found to weigh 10.03 grams, it may be assumed with sufficient accuracy that the error in that 10 cc. amounts to -0.02 cc., or -0.002 for each cubic centimeter (Note 3). In the calculation of corrections the temperature of the water must be taken into account, if this varies more than 4 deg.C. from the laboratory standard temperature, consulting the table of densities of water in the Appendix. From the final data, plot the corrections to be applied so that they may be easily read for each cubic centimeter throughout the burette. The total correction at each 10 cc. may also be written on the burette with a diamond, or etching ink, for permanence of record. [
PREV.   NEXT  
|<   19   20   21   22   23   24   25   26   27   28   29   30   31   32   33   34   35   36   37   38   39   40   41   42   43  
44   45   46   47   48   49   50   51   52   53   54   55   56   57   58   59   60   61   62   63   64   65   66   67   68   >>   >|  



Top keywords:

burette

 

temperature

 

corrections

 

weight

 

Appendix

 

record

 

minutes

 

centimeter

 

volumes

 
reading

apparent
 

notebook

 

differences

 
expiration
 

burettes

 

correction

 
emptying
 

liquid

 
length
 

refill


completed
 

diamond

 

written

 

etching

 

accurately

 

permanence

 

centigrams

 

applied

 

easily

 

Meanwhile


calibration

 

sufficient

 

accuracy

 
assumed
 

varies

 

account

 

calculation

 
amounts
 

densities

 
consulting

represent
 
readings
 

weights

 

volume

 

laboratory

 

standard

 

attempt

 

BURETTES

 
CALIBRATION
 

stopper