FREE BOOKS

Author's List




PREV.   NEXT  
|<   44   45   46   47   48   49   50   51   52   53   54   55   56   57   58   59   60   61   62   63   64   65   66   67   68  
69   70   71   72   73   74   75   76   77   78   79   80   81   82   83   84   85   86   87   88   89   90   91   92   93   >>   >|  
led water before returning it to the iron solution. As soon as the blue appears to be less intense, add the bichromate solution in small portions, finally a single drop at a time, until the point is reached at which no blue color appears after the lapse of thirty seconds from the time of mixing solution and indicator. At the close of the titration a large drop of the iron solution should be taken for the test. To determine the end-point beyond any question, as soon as the thirty seconds have elapsed remove another drop of the solution of the same size as that last taken and mix it with the indicator, placing it beside the last previous test. If this last previous test shows a blue tint in comparison with the fresh mixture, the end-point has not been reached; if no difference can be noted the reaction is complete. Should the end-point be overstepped, a little more of the ferrous solution may be added and the end-point definitely fixed. From the volumes of the solutions used, after applying corrections for burette readings, and, if need be, for the temperature of solutions, calculate the value of the ferrous solution in terms of the oxidizing solution. [Note 1: The accuracy of the work may be much impaired by the removal of unnecessarily large quantities of solution for the tests. At the beginning of the titration, while much ferrous iron is still present, the end of the stirring rod need only be moist with the solution; but at the close of the titration drops of considerable size may properly be taken for the final tests. The stirring rod should be washed to prevent transfer of indicator to the main solution. This cautious removal of solution does not seriously affect the accuracy of the determination, as it will be noted that the volume of the titrated solution is about 200 cc. and the portions removed are very small. Moreover, if the procedure is followed as prescribed, the concentration of unoxidized iron decreases very rapidly as the titration is carried out so that when the final tests are made, though large drops may be taken, the amount of ferrous iron is not sufficient to produce any appreciable error in results. If the end-point is determined as prescribed, it can be as accurately fixed as that of other methods; and if a ferrous solution is at hand, the titration need consume hardly more time than that of the permanganate process to be described later on.] STANDARDIZATION OF POTASSIUM BICHROMATE SOLUTI
PREV.   NEXT  
|<   44   45   46   47   48   49   50   51   52   53   54   55   56   57   58   59   60   61   62   63   64   65   66   67   68  
69   70   71   72   73   74   75   76   77   78   79   80   81   82   83   84   85   86   87   88   89   90   91   92   93   >>   >|  



Top keywords:
solution
 

titration

 

ferrous

 
indicator
 

previous

 

prescribed

 
solutions
 

removal

 

appears

 
stirring

portions

 

thirty

 

seconds

 
reached
 
accuracy
 

titrated

 

removed

 

transfer

 
properly
 

washed


prevent

 

considerable

 

determination

 

affect

 

cautious

 

volume

 

amount

 

permanganate

 

consume

 

accurately


methods

 

process

 
POTASSIUM
 

BICHROMATE

 

SOLUTI

 
STANDARDIZATION
 

determined

 

results

 

rapidly

 

carried


decreases

 

unoxidized

 
procedure
 

concentration

 

produce

 
appreciable
 

sufficient

 
present
 
Moreover
 
elapsed