over posts and into top of jar, pressing them down until they rest firmly on top of plate straps. See that covers are perfectly level and that vent tubes are perpendicular and all at same height above the plates. 8. Heat compound just hot enough so that it will flow. Pour first layer about one quarter inch thick, being careful to cover entire jar cover. Take a soft flame and seal compound around edges of jar and onto posts. 9. Now proceed to burn on top connectors. Cell connectors need only be cleaned in hole left by post, and top of each end. 10. While burning in cell connectors the first layer of compound will have cooled sufficiently to permit the second layer to be applied. This should be done immediately after burning on connectors and while they are still hot. Also heat the terminal posts, as compound will adhere to hot lead more readily than to cold. Start second layer of compound by pouring it over cell connectors and terminal posts, first filling in with sufficient compound to bring level just above the tops of jars. Apply flame, sealing around edges of wood case, being particularly careful to properly seal terminal posts. Let this layer cool thoroughly before applying third layer. 11. The third layer of compound should be applied in the same way as second layer, pouring on connectors and terminal posts first, and filling in to the level of top of wood ease. The spaces between bars of cell connectors will fill and flow over properly if second layer has been allowed to cool and if cell connectors have not been burned up too high. In sealing last layer with flame, care should be taken not to play flame on compound too long as this hardens and burns the compound. Burned compound has no flexibility and will crack readily in service, thus causing the battery to become a "slopper." In pouring compound be sure to have battery setting level so that compound will come up even on all edges of case. Do not move battery after pouring last layer until thoroughly cool. Before installing battery on car be sure that no compound, etc., has been allowed to get onto taper of terminal post, as this will make a poor connection. If this has happened, clean with medium grade sandpaper. VESTA BATTERIES [Fig. 263 Vesta grid with 3-piece isolator] Vesta Isolators. The Vesta plate embodies in its design devices which are intended to hold the plates straight and thus eliminate the buckling and short-circuiting
PREV.   NEXT  
|<   295   296   297   298   299   300   301   302   303   304   305   306   307   308   309   310   311   312   313   314   315   316   317   318   319  
320   321   322   323   324   325   326   327   328   329   330   331   332   333   334   335   336   337   338   339   340   341   342   343   344   >>   >|  



Top keywords:
compound
 

connectors

 

terminal

 

battery

 

pouring

 

readily

 

applied

 
allowed
 

burning

 
filling

plates

 

properly

 

sealing

 

careful

 

causing

 
service
 

burned

 
flexibility
 

hardens

 

Burned


isolator

 
Isolators
 

embodies

 

BATTERIES

 

design

 

eliminate

 

buckling

 
circuiting
 

straight

 

devices


intended
 

sandpaper

 
Before
 

installing

 

slopper

 

setting

 

happened

 

medium

 

connection

 

adhere


entire

 

quarter

 

proceed

 
firmly
 
straps
 

pressing

 
covers
 

height

 

perpendicular

 

perfectly