d for the purpose. The cover may or may not have been attached to the element, depending on how repairs have been made. In either case the procedure is the same as far as sealing is concerned. Assuming the element is attached, stand it upside down, with the cover resting upon two strips, Fig. 242. Lay the string of compound all around the cover channel. Now turn right side up and insert in the jar, taking care that the jar walls enter the cover channels at all points. Apply heat carefully to the edges of the cover and gently force cover clown. If too much compound has been used, so that it squeezes out around the cover, scrape off the excess with a hot knife while forcing cover down. Putting Cells In Case When the covers have all been sealed, put the cells in the case, taking care to put the negative and positive posts in their proper positions, so that each cell connector will connect a positive to a negative post. In Types MHA, KXD, LXRE, and XE, which have wooden spacers between the cells, take care that the spacers are in position and then, after cells are in place, tighten the tie bolts with a screw driver to clamp the jars. In Types DX, LX, LXR, LXRV, SX, XC, XX, and XXV the cells should fit tight in the case; pack them in with thin boards if necessary. Burning on the Cell Connectors See instructions on pages 213 to 216. Charging After Repairing See also instructions on page 373. Not sooner than ten to fifteen hours after filling battery with electrolyte, add electrolyte to restore level if it has fallen. U. S. L. BATTERIES The instructions for rebuilding batteries which have already been given, pages 328 to 374, apply also to all U. S. L. batteries. In working on the old U. S. L. batteries, illustrated in Fig. 243, draw out the electrolyte down to the tops of the plates so that the electrolyte is below the lower end of the vent tube. Then blow out any gas which may have collected under the cover with compressed air or bellows. Never fail to do this, as there is only a small vent hole in the cover through which the gas can escape, the vent tubes extending down into the electrolyte when the cells are properly filled. [Fig. 243 Cross section of old type USL battery] [Fig. 244 Cross section of new type USL battery] Fig. 244 shows the new U. S. L. cover construction. Note that the special cell filling device is no longer used. U. S. L. batteries have lead bushings m
PREV.   NEXT  
|<   284   285   286   287   288   289   290   291   292   293   294   295   296   297   298   299   300   301   302   303   304   305   306   307   308  
309   310   311   312   313   314   315   316   317   318   319   320   321   322   323   324   325   326   327   328   329   330   331   332   333   >>   >|  



Top keywords:
electrolyte
 

batteries

 

battery

 

instructions

 

taking

 

spacers

 

negative

 
section
 

element

 
positive

attached

 

compound

 

filling

 

rebuilding

 

purpose

 
BATTERIES
 

fallen

 
Charging
 

Connectors

 

boards


Burning

 
Repairing
 

fifteen

 

sooner

 

restore

 

extending

 

escape

 
properly
 

filled

 

longer


bushings
 

device

 
construction
 

special

 

plates

 

working

 

illustrated

 

bellows

 

compressed

 

collected


gently

 

carefully

 

channels

 
points
 
excess
 

scrape

 
squeezes
 

repairs

 

strips

 

sealing