ler at 60 degrees Fahrenheit, each pound must have 311 B. t. u. added to it to increase its temperature 371 degrees, which increase must take place before the water can be converted into steam. As it requires 1167.8 B. t. u. to raise one pound of water from 60 to 371 degrees and to convert it into steam at 160 pounds gauge pressure, the 311 degrees required simply to raise the temperature of the water from 60 to 371 degrees will be approximately 27 per cent of the total. If, therefore, the temperature of the water can be increased from 60 to 371 degrees before it is introduced into a boiler by the utilization of heat from some source that would otherwise be wasted, there will be a saving in the fuel required of 311 / 1167.8 = 27 per cent, and there will be a net saving, provided the cost of maintaining and operating the apparatus for securing this saving is less than the value of the heat thus saved. The saving in the fuel due to the heating of feed water by means of heat that would otherwise be wasted may be computed from the formula: 100 (t - t_{i}) Fuel saving per cent = --------------- (1) H + 32 - t_{i} where, t = temperature of feed water after heating, t_{i} = temperature of feed water before heating, and H = total heat above 32 degrees per pound of steam at the boiler pressure. Values of H may be found in Table 23. Table 17 has been computed from this formula to show the fuel saving under the conditions assumed with the boiler operating at 180 pounds gauge pressure. TABLE 17 SAVING IN FUEL, IN PER CENT, BY HEATING FEED WATER GAUGE PRESSURE 180 POUNDS +-----------+-----------------------------------------+ | Initial | Final Temperature--Degrees Fahrenheit | |Temperature|-----+-----+-----+-----+-----+-----+-----| | Fahrenheit| 120 | 140 | 160 | 180 | 200 | 250 | 300 | +-----------+-----+-----+-----+-----+-----+-----+-----+ | 32 | 7.35| 9.02|10.69|12.36|14.04|18.20|22.38| | 35 | 7.12| 8.79|10.46|12.14|13.82|18.00|22.18| | 40 | 6.72| 8.41|10.09|11.77|13.45|17.65|21.86| | 45 | 6.33| 8.02| 9.71|11.40|13.08|17.30|21.52| | 50 | 5.93| 7.63| 9.32|11.02|12.72|16.95|21.19| | 55 | 5.53| 7.24| 8.94|10.64|12.34|16.60|20.86| | 60 | 5.13| 6.84| 8.55|10.27|11.97|16.24|20.52| | 65 | 4.72| 6.44| 8.16| 9.87|11.59|15.88|20.18| | 70 | 4.31| 6.04| 7.77| 9.48|11.21|
PREV.   NEXT  
|<   92   93   94   95   96   97   98   99   100   101   102   103   104   105   106   107   108   109   110   111   112   113   114   115   116  
117   118   119   120   121   122   123   124   125   126   127   128   129   130   131   132   133   134   135   136   137   138   139   140   141   >>   >|  



Top keywords:

degrees

 

saving

 

temperature

 
Fahrenheit
 

heating

 

boiler

 

pressure


Temperature
 

operating

 

computed

 

formula

 

pounds

 
required
 

increase


wasted

 
Degrees
 

source

 

provided

 

utilization

 

increased

 
introduced

maintaining

 
securing
 

apparatus

 

converted

 

simply

 

approximately

 

convert


requires
 

SAVING

 
conditions
 

assumed

 

PRESSURE

 

POUNDS

 
HEATING

Values

 

Initial