which the gas-heater connection is made is not the first fitting and placed as close to the outlet as possible, the water will not circulate freely into the boiler. This connection according to the drawing should be studied and memorized. [Illustration: FIG. 72.--Instantaneous gas heater. Showing circulation heater or booster.] INSTANTANEOUS GAS-HEATER CONNECTIONS.--An instantaneous gas heater is placed in the basement. The copper coil in it is connected at the bottom with the cold-water supply and the top outlet of the coil is connected with the hot-water system of piping. There is no need of a storage tank with this heater. When a faucet is opened in any part of the hot-water piping system, the water passing through the water valve at the heater causes the gas valve to open so that the whole set of burners in the heater is supplied with gas, and the burners are lighted from a pilot light. When the faucet is closed, the gas supply is shut off and the burners are put out. The pilot is lighted all the time. Space will not permit going over these connections in detail. It is a large field and requires considerable thought. SAFETY AND CHECK VALVES.--When a meter is used on a water system, the water company demands that a check valve be placed on the hot-water system to prevent the hot water from being forced back into the meter in case the pressure got strong enough in the boiler. If a check valve is used for this purpose, or for any other purpose, a safety valve must be placed on the boiler piping system to relieve any excessive pressure that may be caused by having the check valve in use. There is today, with meters of modern type, no reason to use a check valve or a safety valve. If an excessive pressure is obtained in the boiler, it is relieved in the water main. When water is heated, it expands. If the heat becomes more intense and steam is formed, the expansion is much greater, and some means must be provided to allow for it. This expansion can be allowed to relieve itself in the water main as explained above. When a check valve is placed on the piping, this means of escape is shut off and a safety valve must be employed. Without these reliefs, the pressure would be so great that an explosion would result. When steel pipe and steel boilers are used for storage tanks and connections, the pipe and tank will shortly start to rust and parts of the piping are stopped up with rust scales. The water also becomes
PREV.   NEXT  
|<   77   78   79   80   81   82   83   84   85   86   87   88   89   90   91   92   93   94   95   96   97   98   99   100   101  
102   103   104   105   106   107   108   109   110   111   112   113   114   >>  



Top keywords:

heater

 

piping

 
system
 

pressure

 

boiler

 

safety

 

burners

 

expansion

 

storage

 
connection

faucet
 

lighted

 

relieve

 
excessive
 
purpose
 

connections

 

outlet

 
connected
 

supply

 
strong

modern

 
caused
 
obtained
 

meters

 

reason

 

scales

 
employed
 

Without

 

reliefs

 
escape

explained
 

explosion

 

shortly

 

boilers

 

result

 

allowed

 

intense

 

formed

 

heated

 
expands

provided
 
greater
 

stopped

 

relieved

 

HEATER

 
CONNECTIONS
 

INSTANTANEOUS

 

booster

 

Showing

 

circulation