own as "extra heavy" or "extra strong." Brass ferrules must be best quality, extra heavy cast brass, not less than 4 inches long and 2-1/4, 3-1/2 and 4-1/2 inches in diameter and not less than the following weights: Diameters Weights 2-1/4 inches 1 pound 0 ounce. 3-1/2 inches 1 pound 12 ounces. 4-1/2 inches 2 pounds 8 ounces. SEC. 19. SOLDER NIPPLES.--Solder nipples must be heavy cast brass or of brass pipe, iron pipe size. When cast they must be not less than the following weights: Diameters Weights 1-1/2 inches 0 pound 8 ounces. 2 inches 0 pound 14 ounces. 2-1/2 inches 1 pound 6 ounces. 3 inches 2 pounds 0 ounce. 4 inches 3 pounds 8 ounces. SEC. 20. BRASS CLEAN-OUTS.--Brass screw caps for clean-outs must be extra heavy, not less than 1/8 inch thick. The screw cap must have a solid square or hexagonal nut not less than 1 inch high and a least diameter of 1-1/2 inches. The body of the clean-out ferrule must be at least equal in weight and thickness to the caulking ferrule for the same size pipe. SEC. 21. LEAD WASTE PIPE.--All lead waste, soil vent and flush pipes must be of the best quality, known in commerce as "_D_," and of not less than the following weights per linear foot: Diameters Weights 1-1/4 inches 2-1/2 pounds. 1-1/2 inches 3 pounds. 2 inches 4 pounds. 3 inches 6 pounds. 4 inches 8 pounds. All lead traps and bends must be of the same weight and thicknesses as their corresponding pipe branches. SEC. 22. ROOF FLASHERS.--Sheet lead for roof flashings must be 6-pound lead and must extend not less than 6 inches from the pipe and the joint made water-tight. SEC. 23. TRAPS FOR BATH TUBS, WATER CLOSETS, ETC.--Every sink, bath tub, basin, water closet, slop hopper, or fixtures having a waste pipe, must be furnished with a trap, which shall be placed as close as practicable to the fixture that it serves and in no case shall it be more than 1 foot. The waste pipe from the bath tub or other fixtures must not be connected with a water-closet trap. SEC. 24. SIZE OF HORIZONTAL AND VERTICAL WASTE PIPES, TRAPS AND BRANCHES.-- Horizontal and vertical Numb
PREV.   NEXT  
|<   98   99   100   101   102   103   104   105   106   107   108   109   110   111   112   113   114   >>  



Top keywords:

inches

 

pounds

 
ounces
 

Weights

 

weights

 

Diameters

 

weight

 

ferrule


fixtures

 
closet
 
quality
 

diameter

 

hopper

 
furnished
 
CLOSETS
 

SOLDER


HORIZONTAL

 
VERTICAL
 

vertical

 
Horizontal
 

BRANCHES

 
connected
 
practicable
 

fixture


extend

 

strong

 
serves
 

ferrules

 

thickness

 
caulking
 
hexagonal
 

square


thicknesses

 

branches

 

FLASHERS

 

NIPPLES

 

linear

 

Solder

 

nipples

 
commerce

flashings