FREE BOOKS

Author's List




PREV.   NEXT  
|<   104   105   106   107   108   109   110   111   112   113   114   115   116   117   118   119   120   121   122   123   124   125   126   127   128  
129   130   131   132   133   134   135   136   137   138   139   140   141   142   143   144   145   146   147   148   149   150   151   152   153   >>   >|  
ectifier] Figure 59 shows the complete ten battery Tungar, Figure 60 gives a side view without the door to show the internal parts. [Fig. 60 Side view, cross-section of 10-battery Tungar rectifier] Figure 61 shows the internal connections for use on a 115-volt A.C. line and Figure 62 the internal connections for use on a 230-volt line. This Tungar is made for a 60-cycle circuit, 25-30, 40-50, and 125-133 cycle circuits. [Fig. 61 Internal wiring for the 10 battery Tungar rectifier for operation on a 115 volts A.C. line] [Fig. 62 Internal wiring for the 10 battery Tungar rectifier for operation on a 230 volts A.C. line] F. The Twenty Battery Tungar Catalogue No. 221514 This Tungar will charge ten 6-volt batteries at 12 amperes, or twenty 6-volt batteries at six amperes. Figure 63 shows the complete rectifier, and Figure 64 shows the rectifier with the side door open to show the internal parts. This rectifier will do the work of two of the ten battery Tungars. It is designed for operation on 60 cycles, 230-volts. On special order it may be obtained for operation on 115 volts and also for other frequencies. The twenty battery Tungar uses two bulbs, each of which is the same as that used in the ten battery Tungar, and has two charging circuits, having an ammeter and regulating switch for each circuit. One snap switch connects both circuits to the supply circuit. The two charging circuits are regulated independently. For example, one circuit may be regulated to three amperes while the other circuit is delivering six amperes. It is also possible, by a system of connections to charge the equivalent of three circuits. For instance, five batteries could be charged at six amperes, five batteries at four amperes, and five batteries at ten amperes. Other corresponding combinations are possible also. General Instructions and Information on Tungars Life of Tungar Bulbs. The life of the Tungar Bulb is rated at 600 to 800 hours, but actually a bulb will give service for 1,200 to 3,000 hours if the user is careful not to overload the bulb by operating it at more than the rated current. [Fig. 63 The 20 battery Tungar rectifier] [Fig. 64 Internal view of the 20 battery Tungar rectifier] Instructions. Complete instructions are furnished with each Tungar outfit, the following being those for the ten battery Tungar. Installation A Tungar should be installed in a clean, dry pl
PREV.   NEXT  
|<   104   105   106   107   108   109   110   111   112   113   114   115   116   117   118   119   120   121   122   123   124   125   126   127   128  
129   130   131   132   133   134   135   136   137   138   139   140   141   142   143   144   145   146   147   148   149   150   151   152   153   >>   >|  



Top keywords:
Tungar
 

battery

 

rectifier

 

amperes

 

Figure

 

circuits

 

batteries

 
circuit
 

operation

 
internal

Internal

 

connections

 

twenty

 

Tungars

 

regulated

 
switch
 

Instructions

 
charging
 

complete

 

wiring


charge

 
instance
 

charged

 

combinations

 

General

 

Information

 

service

 
outfit
 

furnished

 

Complete


instructions
 

Installation

 
installed
 

ectifier

 

current

 

equivalent

 

careful

 

operating

 

overload

 

special


cycles

 

designed

 

obtained

 
Catalogue
 
221514
 

Battery

 
Twenty
 

frequencies

 

supply

 

section