batteries, and also the connections between them. Most troubles are caused by imperfect battery connections. 2. Examine the fuses inside the case. If these are blown or are defective, replace them with 15 ampere fuses, Cat. No. 6335. 3. See that the clip is on the wire of the bulb. 4. The bulb may have a slow leak and not rectify. Try a new bulb, Cat. No. 189049. 5. Have the switch arm make good contact on the regulating switch. If the current on the ammeter is high and cannot be reduced: 1. The ammeter pointer may be sticking; tap it lightly with the hand. The ammeter will not indicate the current correctly if the pointer is not on the zero line when the Tungar is not operating. The pointer may be easily reset by turning slightly the screw on the lower part of the instrument. 2. Be sure that the batteries are not connected with reversed polarity. 3. The alternating-current supply may be abnormally high. If only one three-cell battery is being charged, and the alternating-current supply is slightly high, then the current on the ammeter may be high. The simplest remedy is to connect in another battery or a small amount of resistance. A spare bulb should always be kept on hand and should be tested for at least one complete charge before being placed in reserve. All Tungar bulbs are made as nearly perfect as possible, but occasionally one is damaged in shipment. It may look perfect and yet not operate. For this reason all bulbs should be tried out on receipt. If any bulb is found defective, the tag which accompanies it should be filled out, and bulb and tag should be returned to your dealer or to the nearest office of the General Electric Company, transportation prepaid. Tungar Rectifiers (The following columns omitted from the table below: Catalog Numbers, Dimensions, Net Weight, and Shipping Weight.) Name No. 6V Bats No. 12V Bats. DC Amps DC Volts AC Volts Freq. ------------- ------------- ------- -------- -------- ----- 2 Amp. Tungar 1 (2 amps.) 1 (1 amps.) 1-2 7.5-15 115 60 2 Amp. Tungar 1 (2 amps.) 1 (1 amps.) 1-2 7.5-15 115 60 2 Amp. Tungar 1 (2 amps.) 1 (1 amps.) 1-2 7.5-15 115 40-50 2 Amp. Tungar 1 (2 amps.) 1 (1 amps.) 1-2 7.5-15 115 25-30 2 Amp. Tungar 1 (2 amps.) 1 (1 amps.) 1-2 7.5-15 115 125-133
PREV.   NEXT  
|<   107   108   109   110   111   112   113   114   115   116   117   118   119   120   121   122   123   124   125   126   127   128   129   130   131  
132   133   134   135   136   137   138   139   140   141   142   143   144   145   146   147   148   149   150   151   152   153   154   155   156   >>   >|  



Top keywords:
Tungar
 

current

 

ammeter

 

pointer

 

battery

 

alternating

 

supply

 
perfect
 

Weight

 
switch

slightly

 

defective

 

batteries

 

connections

 

charge

 
reason
 

complete

 
receipt
 

operate

 

shipment


damaged

 
reserve
 

occasionally

 

columns

 

Shipping

 

Catalog

 

Numbers

 
Dimensions
 

nearest

 

office


General
 

dealer

 
accompanies
 

filled

 

returned

 

Electric

 

Company

 

omitted

 

Rectifiers

 

transportation


prepaid

 

189049

 

rectify

 
lightly
 
sticking
 

reduced

 
contact
 

regulating

 

imperfect

 

Examine