FREE BOOKS

Author's List




PREV.   NEXT  
|<   165   166   167   168   169   170   171   172   173   174   175   176   177   178   179   180   181   182   183   184   185   186   187   188   189  
190   191   192   193   194   195   196   197   198   199   200   201   202   203   204   205   206   207   208   209   210   211   212   213   214   >>   >|  
0 XC-9, XX-9 2-1/2 240 DX-11, KXD-7, LXR-9, LXRE-9, XC-11, XE-11 3 290 DX-13, KXD-9, LXR-11, XC-13, XE-13, XX-13 4 385 LXR-13, LXRE-13, XC-15, XE-15, XX-15 4-1/2 430 KXD-11, XC-17, XE-17 5 480 LXRV-15, LXR-15, LXRE-15 5-1/2 525 LX-17, LXR-17, LXRE-17, XC-19, XE-19, XXV-19 6 575 MHA-11, PHC-13 6 575 XC-21, XE-21 6-1/2 625 XC-23 7 675 XC-25 7-1/2 720 4. Occasionally measure the temperature of the electrolyte. Do not allow the temperature to rise above 110 deg. Fahrenheit (120 deg. Fahrenheit in tropical countries). Should the temperature reach 110 deg., stop the charge long enough to allow the temperature to drop below 100 deg.. 5. At the end of the charge, the specific gravity of the electrolyte should be between 1.280 and 1.300 (1.210 and 1.230 in tropical countries). If it is not between these limits adjust it by drawing off some of the electrolyte with the hydrometer and replacing with water if the specific gravity is too high, or with electrolyte of the same specific gravity used in filling the battery, if the specific gravity is too low. 6. Wipe off the top and sides of the battery case with a rag dampened with ammonia to neutralize any electrolyte which may have been spilled. 7. Just before putting the battery into service, give it a high rate discharge test. See page 266. Vesta Batteries 1. Remove vent caps from each cell and fill with electrolyte of 1.300 specific gravity. This electrolyte should not have a temperature greater than 75 deg. Fahrenheit when added to the cells. 2. After the addition of this acid, the battery will begin to heat and it should be left standing from 12 to 24 hours or until it has cooled off. 3. Battery should then be put on charge at the finish charging rate stamped on the name plate. Continue charging at this rate for approximately 48 to 72 hours or until the gravity and voltage readings of each cell stop rising. 4. Care should be taken to see that the temperature of battery does not rise above 110 deg. Fahrenheit. If this occurs., the charging rate should be cut down. 5. The acid in each cell will undoubtedly hav
PREV.   NEXT  
|<   165   166   167   168   169   170   171   172   173   174   175   176   177   178   179   180   181   182   183   184   185   186   187   188   189  
190   191   192   193   194   195   196   197   198   199   200   201   202   203   204   205   206   207   208   209   210   211   212   213   214   >>   >|  



Top keywords:
electrolyte
 

temperature

 

gravity

 

battery

 

specific

 

Fahrenheit

 

charging

 
charge

countries

 
tropical
 

addition

 

standing

 

Remove

 

Batteries

 

greater

 
rising

voltage

 
readings
 

undoubtedly

 

occurs

 

finish

 
cooled
 

Battery

 

stamped


approximately

 

Continue

 

discharge

 
drawing
 

adjust

 

limits

 
replacing
 

hydrometer


Occasionally
 

measure

 

Should

 

putting

 

spilled

 

service

 

filling

 

ammonia


neutralize

 

dampened