FREE BOOKS

Author's List




PREV.   NEXT  
|<   106   107   108   109   110   111   112   113   114   115   116   117   118   119   120   121   122   >>  
ring the experiment proper urine is voided if possible at the end of each period. This offers an opportunity for studying the periodic elimination of nitrogen and helps frequently to throw light upon any peculiarities of metabolism. Even with the use of a long-continued preceding diet of constant composition, it is impossible to rely upon any regular time for defecation or for any definite separation of feces. For many experiments it is impracticable and highly undesirable to have the subject attempt to defecate inside the chamber, and for experiments of short duration the desire to defecate is avoided by emptying the lower bowel with a warm-water enema just before the subject enters the chamber. Emphasis should be laid upon the fact that a moderate amount of water only should be used and only the lower bowel emptied, so as not to increase the desire for defecation. The clothing is usually that of a normal subject, although occasionally experiments have been made to study the influence of various amounts of clothing upon the person. There should be opportunity for a comfortable adjustment of the stethoscope and pneumograph, etc., and the clothing should be warm enough to enable the subject to remain comfortable and quiet during his sojourn inside the chamber. The rectal thermometer, which has previously been carefully calibrated, is removed from a vessel of lukewarm water, smeared with vaseline, and inserted while warm in the rectum to the depth of 10 to 12 centimeters. The lead wires are brought out through the clothing in a convenient position. The stethoscope is attached as nearly as possible over the apex beat of the heart by means of a light harness of canvas. In the use of the Bowles stethoscope, it has been found that the heart-beats can easily be counted if there is but one layer of clothing between the stethoscope and the skin. Usually it is placed directly upon the undershirt of the subject. The pneumograph is placed about the body midway between the nipple and the umbilicus and sufficient traction is put upon the chain or strap which holds it in place to secure a good and clear movement of the tambour for each respiration. The subject is then ready to enter the chamber and, after climbing the stepladder, he descends into the opening of the chair calorimeter, sits in the chair, and is then ready to take care of the material to be handed in to him and adjust himself and his apparatus for the exper
PREV.   NEXT  
|<   106   107   108   109   110   111   112   113   114   115   116   117   118   119   120   121   122   >>  



Top keywords:

subject

 

clothing

 

chamber

 
stethoscope
 
experiments
 

defecate

 

defecation

 
comfortable
 

pneumograph

 

desire


inside

 

opportunity

 

material

 
handed
 

attached

 

harness

 

inserted

 
Bowles
 

canvas

 
vaseline

smeared

 
position
 

convenient

 

rectum

 
centimeters
 

adjust

 

brought

 

apparatus

 

easily

 

nipple


respiration

 

umbilicus

 

sufficient

 

midway

 
lukewarm
 

traction

 
secure
 
tambour
 
movement
 

undershirt


directly

 

counted

 

calorimeter

 
opening
 

Usually

 

climbing

 

stepladder

 
descends
 

person

 
composition