FREE BOOKS

Author's List




PREV.   NEXT  
|<   15   16   17   18   19   20   21   22   23   24   25   26   27   28   29   30   31   32   33   34   35   36   37   38   39  
40   41   42   43   44   45   46   47   48   49   50   51   52   53   54   55   56   57   58   59   60   61   62   63   64   >>   >|  
inutes, depending on the sensitiveness of the plates. The instrument is then removed to the dark room, and the plates developed by immersing them all at once in a solution consisting of four parts potassium oxalate and one part ferrous sulphate. After ten minutes they are removed, fixed, and dried. Their readings are then noted, and compared with those obtained with the silver chloride. The chloride experiment is again performed as soon as the plates have been removed, and the first result confirmed. With some plates it is necessary to make two or three trials before the right exposure can be found; but if the image disappears anywhere between the second and eighth divisions, a satisfactory result may be obtained. The plates were also tested using gaslight instead of daylight. In this case an Argand burner was employed burning five cubic feet of gas per hour. A diaphragm 1 cm. in diameter was placed close to the glass chimney, and the chloride was placed at 10 cm. distance, and exposed to the light coming from the brightest part of the flame, for ten hours. This produced an impression as far as the third division of the scale. The plates were exposed in the sensitometer as usual, except that it was found convenient in several cases to use a larger stop, measuring 0.316 cm. in diameter. The following table gives the absolute sensitiveness of several of the best known kinds of American and foreign plates, when developed with oxalate, in terms of pure silver chloride taken as a standard. As the numbers would be very large, however, if the chloride were taken as a unit, it was thought better to give them in even hundred thousands. SENSITIVENESS OF PLATES. Plates. Daylight. Gaslight. Carbutt transparency 0.7 .. Allen and Rowell 1.3 150 Richardson standard 1.3 10 Marshall and Blair 2.7 140 Blair instantaneous 3.0 140 Carbutt special 4.0 20 Monroe 4.0 25 Wratten and Wainwright 4.0 10 Eastman special 5.3 30 Richardson instantaneous 5.3 20 Walker Reid and Inglis 11.0 600 Edwards 11.0 20 Monckhoven 16.0 120 Beebe 16.0 20 Cramer 16.0 120 It will be noted that the plates most sensi
PREV.   NEXT  
|<   15   16   17   18   19   20   21   22   23   24   25   26   27   28   29   30   31   32   33   34   35   36   37   38   39  
40   41   42   43   44   45   46   47   48   49   50   51   52   53   54   55   56   57   58   59   60   61   62   63   64   >>   >|  



Top keywords:

plates

 

chloride

 

removed

 

obtained

 

instantaneous

 

special

 

result

 

standard

 

sensitiveness

 
Carbutt

Richardson
 

silver

 

exposed

 
oxalate
 

diameter

 

developed

 
impression
 

absolute

 
American
 

foreign


division
 

convenient

 

larger

 

sensitometer

 

measuring

 

transparency

 

Wainwright

 

Eastman

 

Walker

 

Wratten


Marshall

 

Monroe

 

Inglis

 
Cramer
 

Edwards

 

Monckhoven

 

Rowell

 
thought
 

hundred

 
thousands

Gaslight
 
produced
 

Daylight

 

Plates

 

SENSITIVENESS

 

PLATES

 

numbers

 

performed

 
experiment
 

readings