hrough will be made until the breakthrough is complete. Breakthroughs between entries, except as hereinbefore provided, shall be made not exceeding sixty feet apart. Where there is a solid block on one side of a room, breakthroughs shall be made between such room and the adjacent room not to exceed sixty feet apart; where there is a breast or group of rooms, a breakthrough shall be made on one side or the other of each room, except the room adjoining said block, not to exceed forty feet from the outside corner of the breakthrough to the nearest corner of the entrance to the room, and on the opposite side of the same room a breakthrough shall be made, not to exceed eighty feet from the outside corner of the breakthrough to the nearest corner of the entrance to the room, and thereafter breakthroughs shall be made not to exceed eighty feet apart on each side of the room. No working place, except those provided for within a distance of four hundred feet of the principal openings of a mine, shall be driven more than eighty feet in advance of a breakthrough or air-way. The required air current shall be conducted to the breakthrough nearest the face of such entry or room. All breakthroughs between entries, and when necessary between rooms, except the one nearest the working face, shall be closed and made air-tight by brattice, trap doors or other means, so that the current of air in circulation may sweep to the interior of the mine. Brattices between permanent inlet and outlet airways shall be constructed in a substantial manner of brick, masonry, concrete, or non-perishable material. In mines generating fire-damp, so as to be detected by a safety lamp, the air current shall be conducted by brattice, or other means, near enough to the working face to expel the fire-damp, and prevent the accumulation of the same. (Penalty, Sec. 976.) Sec. 927. [=Safe appliances for hoisting persons.=] The owner, lessee or agent of a mine shall provide and maintain safe appliances, approved by the district inspector of mines, for the ingress and egress of persons in each shaft, designated by such owner, lessee or agent as a means of ingress and egress for persons employed therein. When there is but one shaft available for ingress and egress from any unavoidable cause, the appliances therein shall be kept available to persons therein employed at all times. When such appliances in any shaft are rendered unavailable from any cause, the same sh
PREV.   NEXT  
|<   15   16   17   18   19   20   21   22   23   24   25   26   27   28   29   30   31   32   33   34   35   36   37   38   39  
40   41   42   43   44   45   46   47   48   49   50   51   52   53   54   55   56   57   58   59   60   61   62   63   64   >>   >|  



Top keywords:

breakthrough

 

nearest

 

persons

 

exceed

 
corner
 

appliances

 

current

 

working

 

eighty

 

ingress


egress

 

breakthroughs

 

lessee

 
employed
 
brattice
 
conducted
 

provided

 

entrance

 

entries

 

Penalty


adjacent

 

hoisting

 

accumulation

 
prevent
 

detected

 

breast

 
generating
 
safety
 

unavailable

 
provide

complete
 

Breakthroughs

 
hrough
 

unavoidable

 
designated
 

approved

 

rendered

 
maintain
 

district

 

inspector


hereinbefore

 
exceeding
 

material

 

opposite

 
required
 

closed

 

advance

 

principal

 
hundred
 

distance