FREE BOOKS

Author's List




PREV.   NEXT  
|<   69   70   71   72   73   74   75   76   77   78   79   80   81   82   83   84   85   86   87   88   89   90   91   92   93  
94   95   96   97   98   99   100   101   102   103   104   105   106   107   108   109   110   111   112   113   114   115   116   117   118   >>   >|  
providing experience in operation demonstrates that such higher speeds can be obtained with safety. The speed of local trains between City Hall and 96th Street will average about 15 miles an hour, while north of 96th Street on both the West side and East side branches their speed will average about 18 miles an hour, owing to the greater average distance between local stations. As the result of careful consideration of various plans, the company's engineers recommended that all the power required for the operation of the system be generated in a single power house in the form of three-phase alternating current at 11,000 volts, this current to be generated at a frequency of 25 cycles per second, and to be delivered through three-conductor cables to transformers and converters in sub-stations suitably located with reference to the track system, the current there to be transformed and converted to direct current for delivery to the third-rail conductor at a potential of 625 volts. [Illustration: OPERATING GALLERY IN SUB-STATION] [Illustration: GENERAL DIAGRAM OF 11,000 VOLT CIRCUITS IN MAIN POWER STATION] Calculations based upon contemplated schedules require for traction purposes and for heating and lighting cars, a maximum delivery of about 45,000 kilowatts at the third rail. Allowing for losses in the distributing cables, in transformers and converters, this implies a total generating capacity of approximately 50,000 kilowatts, and having in view the possibility of future extensions of the system it was decided to design and construct the power house building for the ultimate reception of eleven 5,000-kilowatt units for traction current in addition to the lighting sets. Each 5,000-kilowatt unit is capable of delivering during rush hours an output of 7,500 kilowatts or approximately 10,000 electrical horse power and, setting aside one unit as a reserve, the contemplated ultimate maximum output of the power plant, therefore, is 75,000 kilowatts, or approximately 100,000 electrical horse power. [Sidenote: _Power House_] The power house is fully described elsewhere in this publication, but it is not inappropriate to refer briefly in this place to certain considerations governing the selection of the generating unit, and the use of engines rather than steam turbines. [Illustration: OIL SWITCHES--MAIN POWER STATION] The 5,000-kilowatt generating unit was chosen because it is practically as large a unit of
PREV.   NEXT  
|<   69   70   71   72   73   74   75   76   77   78   79   80   81   82   83   84   85   86   87   88   89   90   91   92   93  
94   95   96   97   98   99   100   101   102   103   104   105   106   107   108   109   110   111   112   113   114   115   116   117   118   >>   >|  



Top keywords:

current

 
kilowatts
 
average
 

kilowatt

 
system
 
Illustration
 
approximately
 

generating

 

STATION

 

output


generated
 
operation
 

maximum

 
conductor
 
lighting
 

transformers

 
ultimate
 

delivery

 

converters

 

traction


contemplated

 

cables

 

electrical

 

Street

 

stations

 

eleven

 

reception

 
capacity
 
turbines
 

selection


considerations

 

governing

 
implies
 

building

 

construct

 

future

 

extensions

 

possibility

 

addition

 
design

SWITCHES

 

decided

 

engines

 

chosen

 
setting
 

distributing

 

Sidenote

 

reserve

 

practically

 

delivering