he roof for each chimney or other projection. But as the lightning is liable to melt the plate at the point where it enters, especially if the metal be tin or zinc, it is well to solder points at the angles. Some, "to make assurance doubly sure," carry the rods over the whole distance quite to the ground in addition. All authorities consider such a system as this to be as complete a defence against lightning as possible. "If," says Harris, "a building or a ship were perfectly metallic in all its parts, no damage could possibly arise to it when struck by lightning, since the explosive action would vanish the instant the electrical agency entered the metal. In applying lightning-conductors, therefore, as a means of guarding against the destructive effects of lightning, our object should be to carry out this principle in all its generality, and bring the building or ship as nearly as possible into that state of passive electrical resistance it would have supposing the whole mass were iron throughout." After the most careful and extended inquiry possible to him, it is the writer's conclusion that in nearly every case of serious damage by lightning to a building having conductors of any well-known system (except the horizontal, which is not a conductor at all in the usual sense of the word), the failure to protect has been on account of a _defective ground-connection_. The fact is the more surprising as this connection is so much within control and is the least costly part of the system. This fault has arisen from the failure of lightning-rod men, as well as owners of buildings, to apprehend what constitutes a ground-connection for electricity. If the eye sees the end of the conductor pass a short distance beneath the surface, all the connection necessary is thought to be effected, because "the ground is always wet enough in a shower." In the cities it is customary to connect the rod with the water-or gas-pipes in the street, which makes the conduction perfect. In the absence of these it is best to carry the rod to a well; and it is always desirable to enlarge the lower end of the conductor, which may be done by soldering it there to a sheet of copper. If the termination of the line cannot be carried to a well, it should be deeply buried in a bed of coke or charcoal that has been subjected to a red heat. A season or two ago a large barn in the vicinity of Boston was struck by lightning, and though there were rods at th
PREV.   NEXT  
|<   155   156   157   158   159   160   161   162   163   164   165   166   167   168   169   170   171   172   173   174   175   176   177   178   179  
180   181   182   183   184   185   186   187   188   189   190   191   192   193   194   195   196   197   198   199   200   201   202   203   204   >>   >|  



Top keywords:
lightning
 

ground

 
connection
 

building

 
conductor
 

system

 

failure

 
electrical
 

conductors

 

struck


damage
 

distance

 

apprehend

 

arisen

 

buildings

 
owners
 

electricity

 
season
 
constitutes
 

account


defective

 

vicinity

 

Boston

 

protect

 

control

 

beneath

 

costly

 

surprising

 

conduction

 

termination


carried
 

street

 

perfect

 
absence
 

enlarge

 

desirable

 

copper

 

deeply

 
subjected
 
charcoal

effected

 

soldering

 
thought
 

connect

 

buried

 

shower

 

cities

 

customary

 

surface

 

authorities