FREE BOOKS

Author's List




PREV.   NEXT  
|<   83   84   85   86   87   88   89   90   91   92   93   94   95   96   97   98   99   100   101   102   103   104   105   106   107  
108   109   110   111   112   113   114   115   116   117   118   119   120   121   122   123   124   125   126   127   128   129   130   131   132   >>   >|  
from the compound. Until the temperature of the muffle reaches about 1,300 deg.F. carburization does not take place to any useful extent, and consequently it is advisable to avoid the use of any compound from which the carburizing gases are liberated much before that temperature is reached. In the case of steel containing nickel slightly higher temperatures may be used and are really necessary if the same rate of carbon penetration is to be obtained, as the presence of nickel resists the penetration. At higher temperatures the rate of penetration is higher, but not exactly in proportion to the temperature, and the rate is also influenced by the nature of the material and the efficiency of the compound employed. The so-called saturation point of mild steel is reached when the case contains 0.90 per cent of carbon, but this amount is frequently exceeded. Should it be required to ascertain the amount of carbon in a sample at varying depths below the skin this can be done by turning off a small amount after carburizing and analyzing the turnings. This can be repeated several times, and it will probably be found that the proportion of carbon decreases as the test piece is reduced in diameter unless decarburization has taken place. [Illustration: FIG. 42.--Chart showing penetration of carbon.] The chart, Fig. 42, is also a good guide. In order to use the chart it is necessary to harden the sample we desire to test as we would harden a piece of tool steel, and then test by scleroscope. By locating on the chart the point on the horizontal axis which represents the hardness of the sample the curve enables one to determine the approximate amount of carbon present in the case. Should the hardness lack uniformity the soft places can be identified by etching. To accomplish this the sample should be polished after quenching and then washed with a weak solution of nitric acid in alcohol, whereupon the harder points will show up darker than the softer areas. The selection of suitable boxes for carburizing is worthy of a little consideration, and there can be no doubt that in certain cases results are spoiled and considerable expense caused by using unsuitable containers. As far as initial expense goes cast-iron boxes are probably the most expedient, but although they will withstand the necessary temperatures they are liable to split and crack, and when they get out of shape there is much difficulty in straightenin
PREV.   NEXT  
|<   83   84   85   86   87   88   89   90   91   92   93   94   95   96   97   98   99   100   101   102   103   104   105   106   107  
108   109   110   111   112   113   114   115   116   117   118   119   120   121   122   123   124   125   126   127   128   129   130   131   132   >>   >|  



Top keywords:
carbon
 

sample

 

penetration

 

amount

 
temperature
 

compound

 
temperatures
 

higher

 
carburizing
 
expense

Should

 

harden

 

proportion

 

hardness

 

reached

 
nickel
 
withstand
 

spoiled

 

uniformity

 
liable

places

 

identified

 

polished

 

quenching

 

washed

 

etching

 

accomplish

 

present

 
determine
 
locating

scleroscope

 
considerable
 

straightenin

 

difficulty

 

horizontal

 

enables

 

represents

 
approximate
 

worthy

 
initial

suitable

 

unsuitable

 

selection

 
consideration
 
containers
 

results

 

softer

 

expedient

 

alcohol

 

caused